External fire spread is a killer

Global HSE Group shares vital information about the importance of fire safety and external fire spread, highlighting the Grenfell Tower fire.

Global HSE Group share vital information about building external fire spread | PBSA News
Global HSE Group share vital information about building external fire spread.

The Spanish City of Valencia suffered a fatal fire at a pair of large residential apartments in Campanar on the 22 February, 2024. There were 10 fatalities, with many of the residents injured and all made homeless. Windy weather conditions assisted the external wall fire to spread through the combustible Rainscreen cladding, defeating the internal compartmentation, once again showing the world that external fire spread is deadly.

Seven years ago in London, on the 14 June, 2017, a now infamous fatal external wall fire started in the early hours of the morning at Grenfell Tower, North Kensington, killing 72 people. Many of the residents were sleeping. The building had been refurbished with combustible ACM cladding with a Polyethylene core called Reynobond, manufactured by Arconic.

The law of Requirement B4(1) for external fire spread requires: “The external walls of the building shall adequately resist the spread of fire over the walls and from one building to another, having regard to the height, use and position of the building.”

In the Phase 1 report into Grenfell Tower, Inquiry chairman Martin Moore-Bick said: “It is apparent from the findings made in earlier chapters that the external walls of the building did not resist, and indeed actively promoted, the spread of fire. That was principally due to the presence of ACM panels with a polyethylene core, but other materials and other features, including the design and geometry of the facade, also played a role.”

How a fire can spread | Global HSE Group | PBSA News
How a fire can spread.

What is ACM?

ACM is Aluminium Composite Material. The composite has facings of thin, precoated aluminium in large format sheets made rigid by a Polyethylene core. ACM is not a thermal insulation material because the composite has a high thermal conductivity. In a built-up Rainscreen, the ACM screens the separate thermal insulation product from the rain. Grades of ACM have cores which vary in the amount of fire-retardant mineral mixed into the Polyethylene:

  1. 100% Polyethylene as the “standard” grade product. Polyethylene burns fiercely, and in the process melts and burns as a dripping and flowing liquid, spreading fire upwards, sideways, and downwards. The aluminium facings slide off the molten core and provide no protection against rapid fire spread.
  2. 30% Polyethylene with 70% mineral as the “fire retardant” grade product, marketed as FR. This does not mean fire resisting. ACM provides no fire resistance, and ACM FR is still combustible. The fire-retardant minerals mixed into the Polyethylene core delay and slow the speed of fire spread. That delay, combined with fixing detailing, allows ACM manufacturers to achieve a Class B from European Reaction to Fire tests.
  3. 10% Polyethylene with 90% mineral as the “limited combustibility” product, often marketed as Class A2. The A2 in European Reaction to Fire classification requires calorimetry testing to identify the Gross Calorific Value of the material at less than 3.0 MJ/kg, as a measure of the fuel it contains for a fire.
  4. 5% Polyethylene with 95% mineral products have been developed and marketed since Grenfell Tower fire as Class A1, or less than 2.0 MJ/kg of fuel. This is the lowest possible Polyethylene content, and not in common use.

The core material has a direct effect on the combustibility of the ACM panel, and the severity of an external wall fire. The “standard” grade will be around 45.0 MJ/kg. Also, the detailing of the Rainscreen of ACM panels can contribute to fire behaviour in several ways:

  • Fixing: Whether ACM panels are riveted as flat sheets to the aluminium support structure or folded into “cassettes” and hung off the supports, changes the amount of exposure of the Polyethylene core in the fabrication.
  • Formats: Larger formats present fewer exposed edges at the necessary open gaps to provide ventilation to the cavity in the Rainscreen that protects the thermal insulation on the backing wall. This is of marginal effect in a real fire situation when cores are melting and the aluminium facings are falling away to expose large areas of combustible Polyethylene.
  • Cavities: The ventilation and drainage of the cavity keeps the thermal insulation dry and screened from the rain. In a fire, the cavity can provide a “chimney effect”, as the fire spreads rapidly upwards through the external wall, attacking the internal face of the ACM and any combustible membranes or thermal insulation fixed to the backing wall. Fire-resisting cavity barriers of stone wool placed at floor levels, at vertical compartment wall lines, and around windows or doors will reduce the “chimney effect”.

The fire risks associated with ACM cladding were highlighted by the Grenfell Tower fire, which led to the increased scrutiny and regulation of cladding materials.

Correctly identify construction

The Campanar apartment fire was initially reported as a problem of Polyurethane in the external wall construction, but reporting was updated to recognise Polyethylene. The BBC referred to Google Maps Street View from 2008, showing the external wall under construction. Although the graphics were upside down, the protective sheets clearly featured a Larson brand logo, as the range of ACM manufactured by Alucoil. The Campanar apartments had non-combustible insulation, but combustible ACM cladding with a Polyethylene core.

Correct identification of the ACM product matters, as it does for any specification and detailing of external wall construction. The Fire Protection Association (FPA) campaigned with the sensible advice “Know Your Building”.

Governments, as much as building owners and their insurers, are realising there are problems for fire safety with a few types of external wall construction. The risk of deadly and harmful fires involving external walls is a concern, often resulting in overlapping responsibilities among the authors of technical standards.

Registration of buildings with defective external wall construction

Article 31 of the RR(FS)O 2005 is the greatest power that can be exercised by any Fire and Rescue Service in England and Wales. To issue a Prohibition Notice under Article 31 of the Regulatory Reform (Fire Safety) Order 2005 means prohibiting useful occupation* of a building to ensure people’s health and life safety.

*31.—(1) If the enforcing authority is of the opinion that use of premises involves or will involve a risk to relevant persons so serious that use of the premises ought to be prohibited or restricted, the authority may serve on the responsible person or any other person mentioned in article 5(3) a notice (in this Order referred to as “a prohibition notice”).

Before the Grenfell Tower fire, the National Fire Chiefs Council (NFCC) maintained an Enforcement Register of published Notices. However, not all Fire and Rescue Services use the NFCC service as there is no legal duty to compile the NFCC register. Also, data cannot be readily accessed, and is poorly categorised. Therefore, it is not possible to identify the buildings that have been notified by Fire and Rescue Services for a breach of B4(1) in England, or to get a sense of the wider UK.

However, through the newly created Building Safety Regulator (BSR) at the Health and Safety Executive (HSE), the locations of Higher-Risk Buildings (HRBs) are being discovered.

Under Section 65 of the Building Safety Act 2022, an HRB has at least two units of residential accommodation and is either seven storeys or more than 18m in height. That is not the overall building height, but the upper occupied storey height over 18m above ground as Regulation 5(1) of the additional Higher-Risk Buildings (Descriptions and Supplementary Provisions) Regulations 2023.

Owners of an HRB, under the criteria in the Building Safety Act 2022, must appoint “Accountable Persons ” as individuals or organisations to be responsible for the safety of the common parts of the building used by residents, including external walls and roofs. The named Principal Accountable Person (PAP) registers the HRB with the BSR, and updates the register of information with all changes during building occupation.

According to the Institution of Structural Engineers, there is a legacy of 12,500 HRBs registered with the BSR at the HSE, but not all of these will have defective external walls in need of remediation. The 2,000 new HRBs added each year should be without defects.

However, there is no obvious register of the larger additional number of non-HRBs that have external walls known by the Fire and Rescue Service to be in breach of B4(1) in England.

In England and Wales, fire safety responsibilities for all buildings that are not HRBs are defined under the Regulatory Reform (Fire Safety) Order 2005 (RR(FS)O). This legislation designates specific individuals and organisations as “Responsible Persons,” tasked with overseeing and maintaining fire safety within their buildings. This responsibility applies to all workplaces and the common parts of buildings containing two or more domestic premises.

The scope of what constitutes “common parts” of buildings was confirmed by the Fire Safety Act 2021, explicitly including external walls and roofs, which was not a change in meaning from the RR(FS)O 2005. This confirmation highlighted the need for a comprehensive approach to managing potential fire risks associated with the building structure via external wall inspections; an acknowledgement of the risks posed by external wall constructions following a number of significant fire incidents.

Other measures depend on preventing a rapidly spreading external wall fire

The external wall fire at Campanar, much like the tragic Grenfell Tower incident, starkly reminds us that fires originating or spreading via external walls can undermine the internal compartmentation designed to safeguard escape routes. Building Regulations Schedule 1 Requirements B4(1) for the external wall and B4(2) for roofs are crucial as they support the broader suite of fire safety measures -from B1 to B5. Collectively, these requirements must be addressed in a coherent fire strategy to protect building occupants. When a fire spreads through and over external walls and roofs, it often bypasses internal protections, directly threatening the lives of occupants and the integrity of the entire fire safety system.

Occupation denied under B4(1)

An external wall that is physically incapable of supporting rapid fire spread in any condition should be the precondition of occupancy. The decision to deny occupancy is a critical moment at Handover, as Work Stage 6 in the RIBA Plan of Work 2020.

The Fire and Rescue Service are authorised to deny occupancy after it has occurred under the RR(FS)O 2005, clarified by the Fire Safety Act 2021. Fire safety information at Handover should include calorimetry for the external wall construction. A “Responsible Person” should have that basic information, with Building Regulation 38 now listed in both Volumes of Approved Document Part B (2019 as amended 2020 and 2022).

The Building Safety Regulator (BSR) has the power to deny occupancy at Gateway 3 for “Higher-Risk Buildings” under the Building Safety Act 2022, even though the new staff at the Health and Safety Executive (HSE) have overall responsibility for the entire Building Control profession. An “Accountable Person” should have collected the basic calorimetry.

After fatal fires at Grenfell Tower in London and the Campanar apartments in Valencia, it is fortunate that there have not been more fatal fires in occupied buildings with combustible external walls. Concerted action to remediate all buildings is required.